Customer care: info@storeforwellness.com
Whatsapp: 393.9019339 (Messages Only)
Fast shipping
all over the world

(0 Items)

You have no items in your shopping cart.

Elettrostimolatore Globus Genesy 1500 - Technology Security Effectiveness cate to Your Body Service

Genesy 1500, the Top Product, complete of all the currents used in the medical field and of the 3S and Action Now new technologies.

Garanzia: 2 anni


Read More

Be the first to review this product

€899.00
OR

In Stock: Shipping in 3-4 working days

G3554

Order via chat, fax or email

Download the following module and send it to us at the number
+39 02 93435016 or via email info@fabbricabenessere.it

Product Advantages

  • Wide range of programs
  • Easy to use
  • Display simple and easy
  • Visible results and fast
  • Multifunction and multidisciplinary
  • Reliable brand and known

the Complete Stimulator for an enviable Physical Shape!

made in italy

- 11 Rehabilitation - 33 Pain-Tens - 23 Microcurrents - 9 Denervation - 6 Interferentials - 3 Incontinence - 1 Ionophoresis - 53 Sport Training - 29 Fitness - 16 Beauty - 92 Electrotherapy Menu - 84 Action Now - 54 Serial Sequential Stimulation "3S"

The most advanced technology is used to guarantee the most user-friendly and safest use of the stimulator in any treatment situation.

TYPES OF CURRENT

  • EMS
  • TENS
  • MCR
  • KOTZ
  • DENERVATED
  • INTERFERENTIAL
  • IONOPHORESIS

This stimulator is programmable and permits professional users to create and save specific programs with personalized parameters.

ADVANCED TECHNOLOGIES IN THE NEW 2013 RANGE

Globus offers two innovative technologies intended to revolutionize the electrostimulation application in sport and medical fields: the 3S (Serial Sequential Stimulation) technology and ACTION NOW technology.

“3S” SERIAL SEQUENTIAL STIMOLATION: a real revolution in medical and physiotherapic fields as it permits to stimulate the muscles involved in a sequential manner. In this way the natural movement is repeated thanks to the activation in differentiated times of the muscular groups involved.

ACTION NOW: it enables to activate the muscular contraction through an external control managed by an operator. In this way it is possible to link the stimulation to the voluntary contraction to obtain a greater recruitment of the muscular fibers and an important coordinating effect.

SPECIAL FEATURES

MULTI-useR: it permits to store up to 10 different users and to create a library of personalized programs depending on individual aims.

AUTOMATIC MODE (AUTO STIM®): it permits to execute a program in automatic mode with no need of intervening manually in the intensity regulation.

SYNCROSTIM: It is possible to increase the intensity of the 4 channels simultaneously using only one button.

RUN TIME FUNCTION: this function permits to modify the time, the frequency and the pulse amplitude during the treatment

PROGRAMMABLE: 15 free memories, only for EMS and

TENS. 2+2 MODE: it permits to execute two different programs simultaneously.

FAVORITES: it permits to store up to 15 programs for each user

LAST 10: it stores the last 10 executed programs

WORKING TIME: It indicates the total usage time of the device

MY TRAINER: it shows the electrode position on the display

STIM LOCK

BACKLIT DISPLAY

MAINS SUPPLY and BATTERY OPERATED

Look at how to position the electrodes through the videos on our YouTube channel

Warranty Extension alt

Write Your Own Review

Only registered users can write reviews. Please, log in or register

The features!

Channels: 4 independent CHANNELS

Frequency: 0,3 – 150 Hz

Power: 120 mA per channel

Impulse amplitude: 40 – 450 µs

Wave form: Square, biphasic symmetrical compensated

Power supply: rechargeable battery

In compliance with the directive 93/42/CEE-2007/47/CEE

What's in the box

  • 1 Carrying case
  • 1 GLOBUS Genesy 600 electrostimulator unit
  • 4 Electrode connection cables
  • 4 Reusable adhesive electrodes (5x5 cm)
  • 4 Reusable adhesive electrodes (5x9 cm)
  • 1 Battery charger
  • 1 Operating manual

The programs!

REHABILITATION

  • Swollen Ankles
  • Quadriceps Atrophy
  • Hemiplegy-Upper Limbs
  • Hemiplegy-Lower Limbs
  • Recovery after ACL surgery
  • Functional recovery Lower Limbs
  • Multiple Sclerosis-Ankle Re-education
  • Multiple Sclerosis-Leg Re-education
  • Multiple Sclerosis-Muscle Spasms
  • Shoulder Sublaxation Prevention
  • Vastus medialis reinforcement for Patella-femoral syndrome

 

PAIN

  • Conventional Antalgic Tens
  • Menstrual pain
  • Modulated Antalgic Tens
  • Hand Osteoarthritis
  • Endorphinic Tens
  • Post-surgical Pain
  • Chronic Pain
  • Shoulder Pain (S.H. Syndrome)
  • Carpal Tunnel
  • Trapezius Pain
  • Rotator Cuff Tendinitis
  • Low Frequency Antalgic Tens
  • Muscle Pain
  • Sciatica
  • Chronic Lumbago
  • Cervical Pain
  • Bursitis-Tendinitis
  • Bone Fractures
  • Epicondylitis
  • Osteoarthritis

 

IONOPHORESIS

  • Ionophoresis

 

MICROCURRENTS

  • Epicondylitis
  • S. H. Periarthritis
  • Contusion
  • Sciatica
  • Lumbago
  • Acute Pain
  • Articular Pain
  • Stiff Neck
  • Whiplash
  • Shoulder Sprain
  • Knee Sprain
  • Tendon inflammation

 

INCONTINENCE

  • Mixed Incontinence
  • Stress incontinence
  • URGE incontinence

 

INTERFERENTIALS

  • Knee Osteoarthritis
  • Acute Lumbago
  • Cervical Pain
  • Chronic Lumbago
  • Frozen Shoulder
  • Post-surgical Pain

 

DENERVATED

  • Rectangular pulse waveform preset program 1-2-3
  • Triangular pulse waveform preset program 1-2-3
  • Trapezoidal pulse waveform preset program 1-2-3

 

SPORT

  • Capillarization
  • Warm-up
  • Pre-competition Warm-up
  • Active Recovery
  • Maximum Strength
  • Endurance Strength
  • Explosive Strength
  • Aerobic Endurance
  • Reactivity
  • Post-Competition Recovery
  • Decontracting
  • Hypertrophy

 

FITNESS

  • Firming
  • Bio-Pulse Firming
  • Sculpting
  • Bio-Pulse Sculpting
  • Toning
  • Mass Building
  • Body Sculpting
  • Definition
  • Jogging
  • Anaerobic Fitness
  • Aerobic Fitness
  • Cramp Prevention

 

BEAUTY

  • Drainage
  • Lipolysis
  • Toning Massage
  • Skin Tone Improvement
  • Connective Massage
  • Post-Pregnancy Drainage
  • Post-Pregnancy Lipolysis
  • Post-Pregnancy Firming

 

MENU ELECTROTHERAPY

  • 92 programs

 

SERIAL SEQUENTIAL STIMULATION "3S"

  • 54 programs

 

ACTION NOW

  • 84 programs

Current Question

How many sessions of electrostimulation can be carried out weekly?

As regards physical preparation, please refer to the weekly programs included in the Personal Trainer. As regards the applications for fitness and beauty, the frequency of sessions depend on the type of treatment: for tonification, 3-4 weekly sessions every other day are recommended; for lipolysis and drainage, treatments can even be carried out on a daily basis

After how much time can the first results be seen?

The results that can be obtained in the beauty field are obviously subjective. It is however possible to say that, in case of tonification, 3-4 regular and constant weekly sessions can bring good results already after 15 days. For electrolipolysis and electrodrainage, 40 days are necessary. Better and faster results can be achieved if the treatments go alongside with good physical activity and healthy lifestyle.

Does the presence of dermatological diseases like psoriasis, hives and so on preclude the use of electrostimulation?

Yes, it is definitely recommended not to treat any portion of skin with serious skin diseases.

Is it possible to use the electrostimulator during menstrual cycle?

Any interference like early, late, abundant or scarce periods are extremely subjective and variable. It is however recommended to avoid treating the abdomen area during menstrual cycle or soon before or after it.

When I increase intensity to more than 10 mA, intensity goes immediately back to 0. What happened?

As described in user manuals, the appliance is equipped with a power supply control. In case the intensity value is increased to more than 10 mA and the circuit s open, the electrostimulator brings the value back to 0. Before starting any treatment, it is therefore necessary to ensure that the cables are connected, the electrodes are placed on the area to be treated and that the electrodes are not too worn out, because this would decrease their conduction capacity.

What kind of electrodes should be used?

The use adhesive electrodes is recommended, because they are more practical and improve stimulation quality. If used with care, i.e. on clean skin, they can be used even for 25-30 applications.

However, electrodes should be always replaced if they do not adhere perfectly to skin. where should the electrodes be placed?

In the manual, you will find a comprehensive electrode placement guide (it is not necessary to respect the indicated polarity). Please, follow these guidelines. If you want to verify the correct placement of the electrodes, you can use a special motor point pen or follow this empirical method: place the electrode as shown in the picture, start the stimulation and move the electrode with your hand letting the skin slide on the muscle. You will notice a change in contraction according to the different positions of the electrode. Once the point where contraction is greater is identified, decrease channel intensity to zero (0.0 mA), re-position the electrode and increase intensity gradually.

How to use the Y cables.

They permit to use more electrodes on the same channel. This enables, for instance, to stimulate two muscle groups simultaneously with one single channel. They are particularly recommended for medical applications.

Does the power decrease using the Y cables?

The power intensity for each channel does not vary. However, when Y cables are used to split one single channel in two, the current is distributed on a wider muscle area, therefore contraction will be less pronounced. Increase the intensity to obtain the same contraction level. To charge the appliance, switch off the electrostimulator, disconnect the electrode cables and plug the battery charger connector in the apposite socket. The battery charger should be connected to a 220V outlet.

Can electrostimulation hurt me?

It is very unlikely that electrostimulation damages muscles. An important method in this case is to increase intensity gradually while observing the muscle behavior and avoiding to keep the limb completely outstretched. In case of doubt, please contact a specialist.

Is it possible to use the electrostimulator during lactation?

No side effect related to electrostimulation during lactation has been detected so far. It is however advisable not to treat the thoracic area.

Attention

We do not recommend the use of electrical stimulation in the following cases:

  •  Stimulation of the anterior neck (carotid sinus)
  • Patient with a pacemaker
  • Sick of cancer (consult your doctor)
  • Stimulation of the brain region
  • Use on the pain of unknown etiology
  • Wounds and skin diseases
  • Acute trauma
  • Stimulation of recent scars
  • Pregnancy
  • It 'absolutely forbidden the use of electro-ocular and genital area
  • Use of electrostimulation in water
  • Close to the areas to be characterized by the presence of metals and metal fixation infratessutali (such as implants, osteosynthesis material, spirals, screws, plates), when using monophasic currents such as interference and direct current (iontophoresis) .In If you have questions or concerns please contact your physician

The professionals who buy and use equipment for professional purposes, they are directly responsible either legally or criminally. Therefore before purchase we invite you to review the Specific rules for professional products and Technical Specifications of the equipment permitted in these shows.

In particular it should be noted that the use of professional equipment by beauticians / and is regulated by the Ministerial Decree Law 1/90.

This site uses cookies. By continuing to browse this site you are agreeing to our use of cookies. Find out more here.
X